| 管系名称 | 管道规格 mm | 设计参数 | 材 料 | 直径允许偏差 mm | 壁厚允许偏差 mm | |
| 温度 ℃ | 压力 MPa | |||||
| 主蒸汽主管 | ID419×103 | 610 | 27.46 | P92 | +3.18 0 | +15% 0 |
| ID425×103 | ||||||
| 主蒸汽支管 | ID292×73 | 610 | 27.46 | P92 | +2.36 0 | +15% 0 |
| ID305×74 | ||||||
| 高温再热蒸汽 支管 | ID883×51 | 608 | 7.15 | P92 | +4.75 0 | +15% 0 |
| ID889×48 | 6.64 6.27 | +22.5% 0 | ||||
| ID883×45 | ||||||
| 高温再热蒸汽 支管 | ID616×36 | 608 | 7.15 | P92 | +3.96 0 | +22.5% 0 |
| ID635×35 | 6.64 | |||||
| ID616×32 | 6.27 | |||||
| 低温再热蒸汽 主管 | OD1016×35 | 405 | 7.25 | A6911-1/4CrCL22 | ±0.5% | +2.3 -0.3 |
| OD1016×35 | 387 | 6.27 | A672B70CL32 | |||
| 低温再热蒸汽 支管 | OD711×27 | 405 | 7.25 | A6911-1/4CrCL22 | ±0.5% | +1.1 -0.3 |
| OD711×25 | 387 | 6.27 | A672B70CL32 | +1.0 -0.3 | ||
| 高压给水主管 | OD508×55 | 299 | 37 | 15NiCuMoNb5-6-4 | ±1.0% | ±10% |
| 高压给水支管 | OD355.6×43 | 299 | 39 | 15NiCuMoNb5-6-4 | ±1.0% | ±10% |
| OD273×33 | 299 | 39 | ±1.0% | ±10% | ||
| 注1:材料P92标准为ASTM A335,A672B70CL32标准为ASTM A672,A6911-1/4CrCL22标准为ASTM A691,15NiCuMoNb5-6-4标准为EN10216-2。外径管的直径与壁厚允许偏差与相应的钢管标准要求一致。 注2:管道为内径管时,直径允许偏差是指内径允许偏差;管道为外径管时,直径允许偏差为外径允许偏差。 注3:直径允许偏差用百分数表示时,其极限偏差值等于规定外径乘以该百分数;壁厚允许偏差用百分数表示时,其极限偏差值等于规定壁厚乘以该百分数。 | ||||||
| a:对锻制与镗孔管,钢管壁厚上极限偏差为3.2mm,下极限偏差为0。 b:当设计另有规定时,内径控制管的壁厚上极限偏差应符合设计要求。 c:低温再热蒸汽管道局部壁厚上偏差值允许达到表中规定值的1.75倍。 d:对于高压给水管道,当外径D₀ ≥355.6mm且t„/D。>0.10时,允许局部壁厚超过上极限偏差值,超过部分允许达到规定壁厚的5%;当外径D₀ ≤219.1mm时,壁厚允许偏差取±12.5%tn和±0.4mm两者中的较大值。 | ||||||